Chengdu Roots blower factory introduces what is the reason for the burning of Roots blower motor?

time:2022-12-16

 Chengdu Roots Blower FactoryIntroduction Roots blower motor burned because of what?

The motor is the power source of the Roots blower. The burning of the motor means that the Roots blower loses its driving force system and will stop running. There are many reasons for the burning of the Roots blower motor. The more common conditions are mainly the following:

1. Overweight load; This is a common cause of motor damage. The applicable working condition of Roots blower is beyond the standard pressure, resulting in the phenomenon that Roots blower is under load for a long time, and the motor will be damaged.

2, the motor suffered from external damage caused by burning, such as water wet, wire aging, dust intervention too much, this kind of situation may affect the normal operation of the Roots blower motor;

3. The working standard voltage is wrong. Some motors have a rated current of 220V and some motors have a rated current of 380V. If we use a rated current of 220V and still use a current and voltage of 380V when connecting wires, the motors will naturally be burned;

4. The phenomenon of Roots blower motor burning is generally closely related to the engine. For example, the problem of Roots blower impeller, the phenomenon of impeller wheel locking, the motor will also be harmed during normal operation, and the motor is prone to damage; Not only the common faults of the impeller can also cause damage to the motor, but the damage of other parts may also cause the motor to burn, another example is: the reverse installation of the check valve, the installation of non-return valve will expand the pressure of Roots blower in an instant, causing damage to the motor.
 

5. The temperature of Roots blower is too high. Too high temperature will also lead to some situations of Roots blower, such as invalid lubricating oil in gear box, enlarged sliding friction force of transmission gear, problems with transmission belt, abnormality of coupling device in direct transmission system, etc., which may cause other concurrent problems of Roots blower.

6. The quality of the motor's own product and the quality of the motor are also different. The service life of high-quality applications will be long, and the service life of low-quality applications will be short, and the general destruction method of the motor is burned. Therefore, when purchasing and maintaining Roots blowers, we must choose to trust well-known brands with reliable qualifications.

 Chengdu Roots Blower FactoryCauses and solutions of insufficient fan air volume

1. The inlet filter of Roots blower is blocked: clean the inlet filter

2. There is no grease: check the provided oil system and fill the remaining oil

3. Poor lubrication: clean the oil filter and drip injector

4. Deviation of belt: adjust belt tension

5. Pipeline ventilation: finished repairing the pipeline

6. Pipeline too long: reset the pipeline

Chengdu Roots Blower Factory: Well, let's talk about it today. If you need to purchase fans, please contact our Chengdu Roots Blower Factory.

 